| ——Microprocessor control(with timing function) |
| Serve for environmental protection, hygiene and anti-epidemic, pharmaceutical test, workstock and aquatic products etc. which applied in scientific research institute, college and manufacture department. It is a dedicated constant-temperature equipment for analysis of water body, BOD test, cultivation and storage of bacteria, moulds and microorganisms, plant cultivation and seed-breeding test. |
|
1.
|
Polished stainless-steel chamber, semicircular arcs at corners for easy cleaning, and the space between the shelves in the chamber is adjustable. |
| 2. |
Microprocessor temperature controller ensures a precise and reliable control. |
| 3. |
Independent temperature-limiting alarm system ensures experiments run safely. (option) |
| 4. |
Printer connector and RS485 connector are options which can connect printer and computer to record the parameters and the variations of temperature.. (option) |
|
Model |
Cooling incubator |
Cooling incubator (with UV light) |
LRH-70
|
LRH-150
|
LRH-250 |
MJ-70-Ⅰ
|
MJ-150-Ⅰ |
MJ-150-Ⅱ |
MJ-250-Ⅰ |
MJ-250Ⅱ |
| LRH-70F |
LRH-150F |
LRH-250F |
MJ-70F-Ⅰ |
MJ-150F-Ⅰ |
MJ-250F-Ⅱ |
| Temperature Range |
0-60℃ |
0-60℃
|
With humidity:15~45℃ Without humidity:10~45℃ |
0~60℃ |
With humidity:15~45℃ Without humidity:10~45℃
|
Display Resolution
|
0.1℃ |
0.1℃ |
| Temperature Stability |
±0.5℃ |
±0.5℃ |
| Humidity Range |
|
|
|
60~85%RH |
|
60~85% |
| Humidity Stability |
|
|
|
±5%~8%RH |
|
±5%~8%RH |
| Electrical Requirements |
220V 50Hz |
| Ambient Temperature |
+5~30℃ |
| Power consumption |
350W |
450W |
650W |
350W |
450W |
680W |
650W |
850W |
Interior Dimension (mm)W×D×H |
400×350×500 |
500×370×800 |
520×460×1050 |
400×350×500 |
500×370×800 |
520×460×1050 |
600×600×83 |
| External Dimensionl (W×D×H)mm |
530×560×1080 |
600×575×1325 |
620×690×1590 |
530×560×1080 |
600×575×1325 |
620×690×1590 |
740×705×1510 |
| Shelves |
2(pcs) |
3(pcs) |
3(pcs) |
2(pcs) |
3(pcs) |
3(pcs) |
| Timing Range |
1-9999 min |
| Remark |
In addition to all the features of Model Ⅰ,Model Ⅱhas a microprocessor controller for humidity control. F is for R134a refrigerant, imported compressor (DANFOSS) | |
| ※Specification test under non-load condition: ambient temperature is 20℃,and relative humidity is 50%. |
1.
|
Intelligent programable temperature controller |
| 2. |
Printer |
| 3. |
Independent temperature-limiting controller |
| 4. |
Test hole on the left(diameter-50mm) |
| 5. |
BOD socket |
| 6. |
RS485 connector | | | |
|
|