Accessories of HPLC

Stable and fast rising in temperature with high precision

The column oven with big volume can be installed two columns

Optional cooling function to meet the testing of biochemical samples

 

EX1600CO

EX1600COⅡ

Temperature Control Principle

Air circulation heating + semiconductor temperature control

Temperature Range

Room temperature +10

85

Room temperature -10

85

Temperature Control Range

4-85

Temperature Control Precision

±0.1

Chromatographic Columns Installed

Two

Size and Weight

61 (L) × 62 (W) × 26 (H) cm, about 17kg

Power Source

110V/220V

二.EX1600 Pump

Big cam reciprocating parallel infusion, more stable and reliable

 

Automatic rinse device selected. Using the buffer system is more handy

 

Many human-based auxiliary and prompting functions enable users to replace consumables more conveniently

Model

EX1600HP/EX1600LP

EX1600PP

Principle of Liquid Delivery

Big cam-driven, dual-piston reciprocating parallel pump

Max Working Pressure

42Mpa

20Mpa

Flow Range

0.001mL/mim~9.999mL/min

0.01mL/min~40.00mL/min

Flow Precision

RSD<0.06%

RSD1%

Pressure Fluctuation

0.1Mpa

0.2Mpa

GLP Function

Pressure curve, flow curve, recording frequency of piston seal used

Package Size and Weight

61(L)×44(W)×35(H) cm, about 17kg

Power Source

110V/220V

 

三. EX1600 AS

The operation and control of EX1600AS autosampler, which can easily implement the whole process from sample injection to analyzing result, is made entirely by software.

The capacity of EX1600AS can be adjusted from 12 vials to 768 wells. 2 Micro well plates according to SBS standards; 96-well high/low and 384-well low formats; 48-vial or 12-vial trays.

Three injection modes: as Full loop, partial loopfill and μL pickup mode.

The application of advanced sampling technology can achieve rapid sampling and cycle cleaning, and efficient needle track cleaning can achieve low residue.

When using perforated plates or sample bottles, such articles may be used openly or sealedly.
Option of sample cooling function.

Sampling Range

1~5000μL with increment of 1μL (10mL sample loop, optional)

Syringe Volume

500μL (2500μL, optional)

Sample Volume

2×48 Sample plate (2mL sample vial);(12-hole sample plate, 96-hole and 384-hole plate, optional)

Switching Time of Sampling Valve

<100ms

Location Precision of Sampling Needle

0.6nm

Sampling Circulation Time

17s (including 60s for washing needle)

Sampling Method

All sample loop injection, partial sample loop injection, and carrying injection

Sampling Repeatability

All sample loop method RSD<0.3%; partial sample loop method RSD<0.5%; carrying  injection method RSD<1.0%

Sampling Residue

<0.05%

Cooling Range

4℃ to -3℃ room temperature

Noise

<70dB

四.EX1600 UV/UV-Vis Detector

Using all-digital communication for full-process instruments control through RS232 or USB interface

2000-h high-performance deuterium lamp

Unique design of flow cell with double parallel conical bores, effectively amplifying light intensity and energy 

Automatic spectrum scanning

Optional automatic rinse device. When buffer salt is used as mobile phase, it is more convenient and can reduce faults

Model

EX1600UV

EX1600UV

Light Source

D2 lamp

D2 lamp + W lamp

Wavelength Range

180nm-700nm

180nm-900nm

Wavelength Precision

±0.1%

Spectral Bandwidth

8nm

Noise

±0.2×10-5AU

Drift

0.3×10-4AU

Measuring Range

-2AU~2AU

Response Time

0.1,0.2,0.5,1,2, adjustable

Wavelength Time Sequence

Optional change of time wavelength

GLP Function

Time of using lamp, recording D2 and W light energy

Size and Weight

61(L)×44(W)×35(H) cm, about 17kg

Power Source

110V/220V

 

五.EX1600 RI

EX1600RI differential refractive index detector is of excellent sensitivity, stability and reproducibility, and able to detect the most subtle difference of polymeric physical properties, and the analysis result is highly reliable.

Superior operability:

1.   The autostart function can complete the complex operation from the displacement of reference cell solution to verification of stability of the baseline.

2.   Affirmation of the help function can determine device formation.

Excellent Stability:

Optimal temperature control reduces the power-on stabilization time, and thus the excellent stability of the baseline is achieved.

Refraction index range

1.00~1.75

Range

0.2~3.0mL/min

'Recorder output range selection

0.25~512µRIU

noise

2.5nRIU( response; 1.5Sec)

Cell volume

8ul

Drift

0.2µRIU/hwater1mL/minPURGE OFF

Linearity range

600µRIU

Bias adjustment range

10µRIU

Bias decompound energy

50nRIU

 

 