Laminar Flow Clean Bench
Name:  Clean Bench SW-CJ-2FD
Model:  SW-CJ-2FD
 

CLEAN BENCH SERIES:

SUMMARY OF USAGE:

It is a kinds of apparatus with the function of air purified in the operation area. It is widely applicable in the field of medical sanitation, pharmacy, chemical experiments, electron, national defence , accurate apparatus, instruments.  

Feature:

n   Equipped with high efficient air filtering.

n   LED display, eight-step adjustable wind speed.

n   Horizontal flow, open working table.

n   Sorts: single and two people operate

n   Positive pressures filter mounting structure with relative strong tightness.

n   High quality and high efficient filter. Filter efficiency is 99.99%.

n   Blower with low noise.

n   The working table is made of stainless steel(SUS304).

n   Toughened glass moving door and side door.

n   Static plastic spraying

n   Vertical flow& close table for preventing the working area from outside flow.

Technical Parameters

Model: SW-CJ-2FD

Two person one side vertical flow, auto-locating type.

Cleanliness:class100@ 0.5um (Fed209E)

Air velocity:0.3-0.6m/s(adjustable)

Bacterial count:0.5unit/utensil*time(90mm cultivation utensil)

Noise:62dB

ILLumination: 300LX

Vibration/Half peak:3um(X,Y,Z direction)

Power Source:AC220V/50Hz

Max. Consumption(KW):0.3

Weight(Kg):200

Working zone(mm):1300*700*520

Overall Dim.(mm):1460*700*1650

Size & NO.  of  HEPA:600*600*100*

Size & NO.  of  light and UV light:20W*/20W*

 

Name:  Clean Bench SW-CJ-1CU
Model:  SW-CJ-1CU
 

CLEAN BENCH SERIES:

SUMMARY OF USAGE:

It is a kinds of apparatus with the function of air purified in the operation area. It is widely applicable in the field of medical sanitation, pharmacy, chemical experiments, electron, national defence , accurate apparatus, instruments.  

Feature:

n   Equipped with high efficient air filtering.

n   LED display, eight-step adjustable wind speed.

n   Horizontal flow, open working table.

n   Sorts: single and two people operate

n   Positive pressures filter mounting structure with relative strong tightness.

n   High quality and high efficient filter. Filter efficiency is 99.99%.

n   Blower with low noise.

n   The working table is made of stainless steel(SUS304).

n   Toughened glass moving door and side door.

n   Static plastic spraying

n   Vertical flow& close table for preventing the working area from outside flow.

Technical Parameters:

Model: SW-CJ-2CU

Two person horizontal flow.

Cleanliness:class100@ 0.5um (Fed209E)

Air velocity:0.3-0.6m/s(adjustable)

Bacterial count:0.5unit/utensil*time(90mm cultivation utensil)

Noise:62dB

ILLumination: 300LX

Vibration/Half peak:3um(X,Y,Z direction)

Power Source:AC220V/50Hz

Max. Consumption(KW):0.3

Weight(Kg):200

Working zone(mm):1570*480*570

Overall Dim.(mm):1570*790*1380

Size & NO.  of  HEPA:600*600*100*  820*600*100*

Size & NO.  of  light and UV light:40W*/40W*

 

Name:  Biohazard Safety Cabinet BSC-1300IIA2
Model:  BSC-1300IIA2
  BIOHAZARD SAFETY CABINET SERIES:

SUMMARY OF USAGE:

Biological safety cabinets are applied in microorganism, biology engine and some place which have rigorous requirement to working environment. This kind of cabinets can prevent efficiently pathogenic microorganism , microorganism, genes and etc. from diffusing. Also the cabinets can obstruct the contamination to operator from these materials. So the cabinets can supply non-bacteria and non-dust working condition for treatment, medical producing and science research.

PRODUCT FEATURE:

n    Fission structure: The front panels are detachable and easier to remove for filter and filter.

n    Visible window: with anti-ultraviolet toughened glass and the height of glass can be adjustable. If the height is higher than safe level, the audible and visual alarm will be opened.

n    The cabinet: all be manufactured by 304# stainless steel material and the left, right and back bins of cabinet are manufactured together with arc angle will make easier to clean the side of cabinet. 

CABINET FEATURE:

n    Contaminated Pressure Plenum: Negative Unitized drain pan beneath the work surface allows best arm position above the user's lap.

n    The airflow design creates a more impenetrable air barrier or momentum air curtain at the front of the cabinet, increasing the cabinet's protective capabilities and avoiding cross infection.

n    This kind of design standard is comply with NSF49 II standard. With strong wind from the draught intake in side of cabinet, which will clear the round airflow up in lateral cabinet and prohibit the moving of contamination.

n    Ultra-high efficiency filter system: input and output of air will be filtrated by ULPA filter and its efficiency is more than 99.999%. the pressure sensor will watch the working condition of filter from time to time and alarm the operator if the pressure is over the setting value.

n    Ultraviolet light safety: the UV light cannot be opened when the fan, visible window and fluorescent light are running.

n    Interlock function for two fans(blower and exhaust fan): when the exhaust fan stops, the blower will sop automatically and alarm device will begin to work. When the blower stops, the exhaust fan will continue to work and the alarm system will indicate the fault of blower.

DISPLAYING DATA IN THE SCREEN:

n    air-exhaust value(m3/h)

n    the velocity of air laminar flow (m/s)

n    counter for exhaust fan

n    counter for blower 

SAFETY CONTROL SYSTEM:

n        alarm for low air exhaust value

n       alarm for low air-velocity of down laminar flow

n        alarm for fault of exhaust fan

n       alarm for closing condition of visible window

n       when the visible window is opened, the UV light will be closed automatically

n      when the fluorescent light is on working, the UV light will be closed automatically

n       when the blower begin to work and then the UV light will be off after air laminar flow is created.

n      The blower will be off automatically if the exhaust fan happens some trouble. The exhaust fan will increased his rotate speed automatically in order to keep the working space in negative pressure inside cabinet in case something wrong happens with the blower.

n       Microprocessor will counteract the gradually increased resistance in filter. It will keep air inflow and downflow in normal condition under any conditions.

Technical Parameters:

Model: BSC-1300 II A2(not use for medicine)

Suitable for two person

Cleanliness: Classs100(Fed209E)0.5um3.5/L

Inflow airflow velocities: 0.5m/s

Down airflow velocities: 0.35m/s

Safety: Personal protection: All: CFU10, Not all: CFU5

             Product protection: CFU5

             Overlapping pollution: CFU2

Vibration/half peak: 0.5um

Noise: 65dB

Power supplu/consumption: AC220V/50Hz/500W

Working zone: 1340*600*680

Overall DIM.: 1500*810*1540

Size of wind sending filter: 1340*530*70*

Size of wind exhaust filter: 700*480*90*

Size of light lamp and UV lamp: 40W*/30W*

 

Copyright 2005 HEBINSTRUMENT        ALL Rights Reserved