◆ Air temp.servo-controlled by computer;
◆ Separate setting temp.and real temp.display windows;
◆ Five self-check alarms.
SPECIFICATIONS
|
Model
Specifications |
YXK-6G |
|
Power Source |
220V, 50HZ |
|
Power consumption |
≤300VA |
|
Air Temperature Control Range |
25~37℃ |
|
Skin Temperature Servocontrol
Range |
—— |
|
Control Range (High Temperature
Mode) |
—— |
|
Temperature Display Resolution |
0.1℃ |
|
Temperature Stability |
〈0.5℃ |
|
Air Temperature Alarm |
±3℃ |
|
Skin Temperature Alarm |
—— |
|
Self-check Alarms |
Over temperature, Air Flow, Temperature Error, Power fail |
|
Digital Humidity Display |
—— |
|
Humidity Display Resolution |
—— |
|
Connector |
—— |
|
Noise level in Hood |
≤55db |
|
Walls of Hood |
Single |
|
Mattress Titing |
—— |
|
Access |
front | | |
|
|
|
◆ Air temp. and skin temp.servo-controlled by computer;
◆ Separate setting temp. and real temp. display windows;
◆ Whole trough(AL)
◆ Available mattress tilting adjustment;
◆ With a phototherapy(blue light) unit and timer. | |
|
|
|
◆ Air temp.and skin temp.servo-controlled by computer;
◆ Whole trough(AL);
◆ Available mattress tilting adjustment
specifications
|
Model
Specifications |
YXK-7G |
|
Power Source |
220V, 50HZ |
|
Power consumption |
≤300VA |
|
Air Temperature Control Range |
25~37℃ |
|
Skin Temperature Servocontrol Range |
30~37℃ |
|
Control Range (High Temperature Mode) |
—— |
|
Temperature Display Resolution |
0.1℃ |
|
Temperature Stability |
〈0.5℃ |
|
Air Temperature Alarm |
±3℃ |
|
Skin Temperature Alarm |
±1.0℃ |
|
Self-check Alarms |
Over temperature, Air Flow, Skin temp. sensor, Temperature Error, Power fail |
|
Digital Humidity Display |
—— |
|
Humidity Display Resolution |
1% |
|
Connector |
—— |
|
Noise level in Hood |
≤55db |
|
Walls of Hood |
Single |
|
Mattress Titing |
√ |
|
Access |
Side | | |
|
|
|
◆ Air temp.and skin temp.servo-controlled by computer;
◆ Available mattress tilting adjustment;
◆ Whole trough(AL);
◆ ≥37℃ temperature setting;
◆ Humidity display
◆ RS-232 connector;
◆ Addedwith guardrail.
SPECIFICATIONS
● Air Temperature Control Range:25-37℃
● Skin Temperature Control Range:30-37℃
● Temperature Display Resolution:0.1℃
● Temperature Stability:∠0.5℃
|
Model
Specifications |
YXK-5GB |
|
Power Source |
220V, 50HZ |
|
Power consumption |
≤450VA |
|
Air Temperature Control Range |
25~37℃ |
|
Skin Temperature Servocontrol Range |
30~37℃ |
|
Control Range (High Temperature Mode) |
37.1~38℃ |
|
Temperature Display Resolution |
0.1℃ |
|
Temperature Stability |
〈0.5℃ |
|
Air Temperature Alarm |
+1.5℃/-2.5℃ |
|
Skin Temperature Alarm |
±1.0℃ |
|
Self-check Alarms |
Over temperature, Air Flow, Skin temp. sensor, Temperature Error, Power fail |
|
Digital Humidity Display |
10~99% |
|
Humidity Display Resolution |
1% |
|
Connector |
RS-232 |
|
Noise level in Hood |
≤55db |
|
Walls of Hood |
Single |
|
Mattress Titing |
√ |
|
Access |
Side | | |
|
|
YXK-2000G Infant Incubator |
|
◆ Air temp.and skin temp.servo-controlled by computer;
◆ Double walls hood;
◆ Whole trough(AL);
◆ Free step mattress tilting adjustment;
◆ ≥37℃ temperature setting;
◆ Humidity display;
◆ RS-232 connecot.
SPECIFICATIONS
● Air Temperature Control Range:25-37℃
● Skin Temperature Control Range:30-37℃
● Temperature Display Resolution:0.1℃
● Temperature Stability:∠0.5℃
|
Model
Specifications |
YXK-2000G |
|
Power Source |
220V, 50HZ |
|
Power consumption |
≤450VA |
|
Air Temperature Control Range |
25~37℃ |
|
Skin Temperature Servocontrol
Range |
30~37℃ |
|
Control Range (High Temperature
Mode) |
37.1~38℃ |
|
Temperature Display Resolution |
0.1℃ |
|
Temperature Stability |
〈0.5℃ |
|
Air Temperature Alarm |
+1.5℃/-2.5℃ |
|
Skin Temperature Alarm |
±1.0℃ |
|
Self-check Alarms |
Over temperature, Air Flow, Skin temp. sensor, Temperature Error, Power fail |
|
Digital Humidity Display |
10~99% |
|
Humidity Display Resolution |
1% |
|
Connector |
RS-232 |
|
Noise level in Hood |
≤55db |
|
Walls of Hood |
Double |
|
Mattress Titing |
√ |
|
Access |
Front | | | |
|
|