1-5L Lab Scale Single Layer Glass Reactor

 

 

Technicai Parameters:

Basic parameter

Type

HB-1L

Glass material

GG-17

Main stents

Stainless steel

Reaction bottle volume

Sphere 1L

Number of kettle lid bottle

4

Reaction temperature of reactor

-80-250

Vacuum

0.098Mpa

Stirring running speed

0-800pm

Stirring axis diameter

8mm

Motor power

40W

Heating power

1.5KW

Voltage/frequency (V/Hz)

220V/50Hz

Exterior size (mm*mm*mm)

320*330*1000

Baffle size (mm*mm*mm)

280*330mm

Bath size (mm*mm)

Stainless steel    250*140mm

Packing size (mm*mm*mm)

800*480*450  0.19square 

Packing weight KG

24

 

Function configurations  

Speed regulation

Stepless speed regulation

Rotary speed display

Digital display

Temperature display in bath

Digital display

Sealing method

PTFE sealing,¢50flange stirring opening

Condenser

Vertical 40*400mm24# standard opening 

Dropping device

250mlconstant pressure funnel, 24# standard opening

Temperature measuring tube

19# standard opening

Collecting device

Adapter with collecting bottle

Vacuum display

Vacuum meter

Stirring connection method

Cardan joint connected

Stirring stick

Writing stainless stick, coated by PTFE

Technicai Parameters:

Basic parameter

Type

HB-2L

 

Glass material

GG-17

 

Main stents

Stainless steel

 

Reaction bottle volume

Sphere 2L

 

Number of kettle lid bottle

4

 

Reaction temperature of reactor

-80-250

 

Vacuum

0.098Mpa

 

Stirring running speed

0-800pm

 

Stirring axis diameter

8mm

 

Motor power

40W

 

Heating power

1.5KW

 

Voltage/frequency (V/Hz)

220V/50Hz

 

Exterior size (mm*mm*mm)

320*330*1000

 

Baffle size (mm*mm*mm)

280*330mm

 

Bath size (mm*mm)

Stainless steel    250*140mm

 

Packing size (mm*mm*mm)

800*480*450  0.18 square

 

Packing weight KG

25

 

Function configurations  

Speed regulation

Stepless speed regulation

 

Rotary speed display

Digital display

 

Temperature display in bath

Digital display

 

Sealing method

PTFE sealing,¢50flange stirring opening

 

Condenser

Vertical 40*400mm24# standard opening

 

Instillment device

250mlconstant pressure funnel, 24# standard opening

 

Temperature measuring tube

19# standard opening

 

Collecting device

Adapter with collecting bottle

 

Vacuum display

Vacuum meter

 

Stirring connection method

Cardan joint connected

 

Stirring stick

Writing stainless stick, coated by PTFE

Optional configurations

Explosion-proof

Ex-frequency inverter, Ex-motor, EX40W,  0-1400 running speed

 

Temperature display in reactor

Digital display

Our laboratory glass and instruments are developed independently, we can manufacture according to customers demands.

Technicai Parameters:


 

 

 

Basic parameter

Type

HB-3L

Glass material

GG-17

Main stents

Stainless steel

Reaction bottle volume

Sphere 3L

Number of kettle lid bottle

5

Reaction temperature of reactor

-80-250

Vacuum

0.098Mpa

Stirring running speed

0-800pm

Stirring axis diameter

8mm

Motor power

90W

Heating power

2KW

Voltage/frequency (V/Hz)

220V/50Hz

Exterior size (mm*mm*mm)

400*330*1200

Baffle size (mm*mm*mm)

350*330mm

Bath size (mm*mm)

Stainless steel    250*170mm

Packing size (mm*mm*mm)

1000*480*480  0.23square

Packing weight KG

27

 

Function configurations  

Speed regulation

Stepless speed regulation

Rotary speed display

Digital display

Temperature display in bath

Digital display

Sealing method

PTFE sealing,¢50flange stirring opening

Condenser

Vertical 60*450mm24# standard opening

Dropping device

500ml constant pressure funnel, 29# standard opening

Temperature measuring tube

19# standard opening

Collecting device

Adapter with collecting bottle

Vacuum display

Vacuum meter

Stirring connection method

Cardan joint connected

Stirring stick

Writing stainless stick, coated by PTFE

Optional configurations

Explosion-proof

Ex-frequency inverter, Ex-motor, EX40W,  0-1400 running speed

Temperature display in reactor

Digital display

Our laboratory glass and instruments are developed independently, we can manufacture according to customers demands.

Technicai Parameters

Basic parameter

Type

HB-5L

Glass material

GG-17

Main stents

Stainless steel

Reaction bottle volume

Sphere 5L

Number of kettle lid bottle

5

Reaction temperature of reactor

-80-250

Vacuum

0.098Mpa

Stirring running speed

0-800pm

Stirring axis diameter

8mm

Motor power

90W

Heating power

2KW

Voltage/frequency (V/Hz)

220V/50Hz

Exterior size (mm*mm*mm)

430*330*1200

Baffle size (mm*mm*mm)

410*325mm

Bath size (mm*mm)

Stainless steel    280*170mm

Packing size (mm*mm*mm)

1000*480*480  0.23square

Packing weight KG

30

 

Function configurations  

Speed regulation

Stepless speed regulation

Rotary speed display

Digital display

Temperature display in bath

Digital display

Sealing method

PTFE sealing,¢50flange stirring opening

Condenser

Vertical 60*450mm24# standard opening

Dropping device

500ml constant pressure funnel, 29# standard opening

Temperature measuring tube

19# standard opening

Collecting device

Adapter with collecting bottle

Vacuum display

Vacuum meter

Stirring connection method

Cardan joint connected

Stirring stick

Writing stainless stick, coated by PTFE

Optional configurations

Explosion-proof

Ex-frequency inverter, Ex-motor EX60W,  0-1400 running speed

Temperature display in reactor

Digital display

Dumping material device

PTFE dumping valve,  60flange opening

Our laboratory glass and instruments are developed independently, we can manufacture according to customers demands.

 

Copyright 2005 HEBINSTRUMENT        ALL Rights Reserved